PORTABLE SHRINK FIT

H6i

Learn more

Heat & Cool in Seconds

H6i is a full 6kW shrink fit machine that fits in one hand and runs off a wall outlet.

25kg, Truly Portable

Carry it to the machine instead of carrying tooling to a fixed station.

No Water Line Needed

Air-cooled design runs anywhere with a power outlet.

One-Touch Barcode Heat

Scan a tool holder and the right heating profile loads automatically.

PORTABLE SHRINK FIT

Low-Temp Air-Cooled Shrink Fit Machine

Model: H6i

Request a Quote
Net Weight, Portable

25KG

Temperature Control Accuracy

5C

Rated Power

6KW

K620, K635H, K655

3 Coils

Product Positioning

Portable Intelligent Shrink Fit Tool Holder Heating Device

Core Functions

Shrink Fit Tool Holder Heating, Tool Assembly/Disassembly, Intelligent Temp Control, Scan-to-Identify One-Touch Heating

Dimensions & Weight

Main Unit Dimensions (L×W×H)

540mm×400mm×780mm

Packaging Dimensions (L×W×H)

660mm×510mm×890mm

Equipment Net Weight

25KG

Equipment Gross Weight (Including Packaging)

30KG

Equipment Footprint

540mm×400mm

Heating Coil Maximum Stroke

400mm

Cooling Panel Maximum Stroke

400mm

Core Performance Parameters

Rated Power

6KW

Rated Voltage

AC220V

Rated Frequency

50/60Hz

Rated Current

27A

Input Air Supply Requirement

0.6-0.8 MPa (Dry Filtered, Water & Dust Free)

Heating Method

Electromagnetic Induction Heating

Cooling Method

Air Cooling

Temperature Control Accuracy

±5℃

Maximum Heating Temperature

/

Intelligent Temperature Control Function

Yes

Heating System Core Parameters

Comparison Table
  • Coil Inner Diameter: K620 20mm, K635H 35mm, K655 Power 55mm
  • Maximum Shrink Fit Outer Diameter: K620 15mm, K635H 30mm, K655 Power 50mm
  • Coil Height: K620 27.5mm, K635H 42mm, K655 Power 62mm
  • Coil Effective Heating Thickness: K620 19mm, K635H 38mm, K655 Power 52mm
  • Heat Shield Ring: K620 ☒, K635H ☒, K655 Power ☑
  • Heating Range: K620 3-6mm, K635H 3-12mm, K655 Power 12-32mm
  • Alloy Steel Heating Time: K620 3-6s, K635H 4-9s, K655 Power 8-15s
  • Stainless Steel Heating Time: K620 8-15s, K635H 10-30s, K655 Power 30-45s
Coil Replacement Method

Quick-Change Type

Intelligent Induction Switching

Yes

Coil Positioning Accuracy

M

Compatible Heat Shield Ring Specifications

HG55SR1825

Electrical System Parameters

Power Type

Single-Phase AC

Allowable Voltage Fluctuation Range

AC220V±10%

Insulation Class

Class F

Protection Rating

IP54

Grounding Requirement

Reliable grounding required, grounding resistance ≤1Ω

Overcurrent Protection

Supported

Overvoltage Protection

Supported

Overtemperature Protection

Supported

Short Circuit Protection

Supported

Cooling System Parameters

Cooling Method

Forced Air Cooling

Cooling Stroke

45-400mm

Cooling Efficiency

Tool holder cools from 300°C to ambient ≤60s

Air Supply Filtration Requirement

Three-Stage Filtration, Water-Free, Dust-Free, Oil-Free

Function Configuration

Core Function 1

Scan Recognition

Core Function 2

One-Touch Heating

Core Function 3

Quick-Change Coil

Core Function 4

Intelligent Induction Switching System

Core Function 5

Heats Both Stainless Steel and Alloy Steel

Core Function 6

Automatic Coil Model Recognition

Core Function 7

Precision Temperature Control

Core Function 8

Coil Overtemperature Warning

Core Function 9

Overtemperature Automatic Protection

Core Function 10

Built-in Parameter Library

Core Function 11

Supports Multi-Spec Tool Holder Parameter Presets

Core Function 12

Manual/Auto Dual Mode Switching

Safety Protection Configuration

Overtemperature Protection

Dual Overtemperature Protection (Coil + Main Unit), Auto Stop Heating & Alarm Power-Off on Overtemperature

Overcurrent/Short Circuit Protection

Auto Trip Protection on Electrical Overload & Short Circuit

Leakage Protection

No

Air Supply Abnormality Protection

No

Coil Abnormality Protection

No

Over-Travel Protection

Heating Coil/Cooling Head Manual Control Movement, with Physical Stop Hard Limit

Emergency Stop Button

No

Safety Warning Labels

High-Temp & High-Pressure Safety Warning Labels on Both Body and Heating Coil

Insulation Protection

Double Insulation for High-Voltage Parts, Prevents Electric Shock Risk

Human-Machine Interaction System

Display Specification

4.3-inch HD LCD Touch Screen

Display Resolution

480×272

Operation Method

Full Touch Operation

Language Support

Chinese/English/Korean Trilingual Switching

Parameter Settings

Visual Parameter Settings, One-Touch Recall of Preset Parameters

Data Display

Real-Time Display of Heating Time, Cooling Time, Assembly/Disassembly Time

Fault Prompt

Chinese Fault Codes

Operation Guide

Intelligent Barcode Scanner Simplifies HMI, Quick Onboarding for Novices

Accessories & Optional Systems

Standard Accessory 1

Product Manual, Warranty Card

Standard Accessory 2

Shrink Fit Machine Certificate of Conformity

Standard Accessory 3

Password Letter

Standard Accessory 4

Operation Video QR Code

Standard Accessory 5 - Coolant

Not applicable for air-cooled shrink fit machine

Optional Accessory - Quick-Change Coil

K620, K655 Power

Optional Accessory - Handheld Barcode Scanner

QR-LHV01

Optional Accessory - Retaining Ring

HP-K3, HP-K4, HP-K5, etc.

Optional Accessory - Tool Removal Pliers

HP-LH7-N

Optional Accessory - Air Filter

AF300

Optional Accessory - Heat-Resistant Gloves

HP-GT-N

Optional Accessory - Heat Shield Ring

HG55SR1825

After-Sales Support Services

Full Machine Warranty Term

1 year (non-human-induced damage)

Technical Support

7×24 Online Technical Support, Remote Troubleshooting Guidance

On-Site Service

Nationwide on-site installation, debugging & repair service available (except remote areas)

Accessories Supply

Lifetime supply of original factory accessories, shipped within 48 hours

Training Service

Free equipment operation & maintenance training

Software Upgrade

Lifetime Free Equipment Control System Software Upgrade

Maintenance Requirements

Daily Maintenance

Clean Body & Heating Coil After Daily Use, Check Air Supply Lines for Leaks

Weekly Maintenance

Clean Air Filter Element Weekly, Check Electrical Connections for Looseness

Monthly Maintenance

Check Heating Coil Insulation Monthly, Calibrate Temperature Sensor, Lubricate Moving Parts

Quarterly Maintenance

Comprehensive Quarterly Check of Electrical, Cooling & Mechanical Transmission System Performance

Annual Maintenance

Annual Return-to-Factory or On-Site Comprehensive Inspection, Replace Aged Seals, Cables and Other Wear Parts

Storage Requirements

Store in Dry, Ventilated, Corrosive-Gas-Free Environment, Temp -10°C~40°C, RH ≤85%

Transportation Requirements

Use Original Packaging During Transport, Avoid Severe Impact, Inversion, Rain Exposure

Operating Environment Requirements

Operating Temp 5°C~40°C, RH ≤80%, No Dust, No Corrosive Gas, No Strong Electromagnetic Interference

Machine Safety Requirements & Compliance

CE Safety Certification

Meets

3C Safety Certification

Not Applicable

FCC Safety Certification

Meets

EAL Safety Certification

Meets

UKCA Safety Certification

Meets

PSE Safety Certification

Meets

KC Safety Certification

Meets

Mechanical Protection

Meets

Mechanical Structure

Meets

Leveling Feet

Meets

Movable Guard

Not Applicable

Observation Window

Not Applicable

GET A QUOTE

Need help specifying the right H6i configuration?

HIPPSC's engineering team can help match tool holder compatibility, power requirements, and integration needs to your workshop.