RoboFit Ultra Low-Temp Temperature-Controlled Automatic Shrink Fit Machine

Tool Automation Ecosystem

Model: RoboFit Ultra

Low-Temp Temperature-Controlled Automatic Shrink Fit Machine

Intelligent Shrink Fit Tool Holder Heating Device, Member of Tool Automation Ecosystem Core functions: Shrink Fit Tool Holder Heating, Tool Assembly/Disassembly, Intelligent Temp Control, Scan-to-Identify One-Touch Heating.

6KW
Rated Power
5C
Temperature Control Accuracy
15s
Water-Cooled Cooldown, 300C to Ambient
6-15s
Alloy Steel Heating Time

Basic Information

Product NameLow-Temp Temperature-Controlled Automatic Shrink Fit Machine
Product ModelRoboFit Ultra
Product PositioningIntelligent Shrink Fit Tool Holder Heating Device, Member of Tool Automation Ecosystem
Core FunctionsShrink Fit Tool Holder Heating, Tool Assembly/Disassembly, Intelligent Temp Control, Scan-to-Identify One-Touch Heating
Applicable IndustriesCNC Machining, Mold Manufacturing, Precision Machinery, Aerospace, Automotive Parts Machining, etc.
Compatible Tool Holder TypesISO, BT, BBT, HSK, CAT, SK

Dimensions & Weight

Main Unit Dimensions (L×W×H)950×710×1850mm
Packaging Dimensions (L×W×H)1050×810×1950mm
Equipment Net Weight185KG
Equipment Gross Weight (Including Packaging)325KG
Equipment Footprint950×710mm
Heating Coil Maximum Stroke500
Cooling Panel Maximum Stroke300

Core Performance Parameters

Rated Power6KW
Rated VoltageAC220V
Rated Frequency50/60Hz
Rated Current27A
Input Air Supply Requirement0.6-0.8 MPa (Dry Filtered, Water & Dust Free)
Heating MethodElectromagnetic Induction Heating
Cooling MethodWater Cooling
Temperature Control Accuracy±5℃
Maximum Heating Temperature/
Coil Intelligent Temperature Control FunctionYes

Heating System Core Parameters

Heating Coil ModelK635H Ultra
Coil Inner Diameter35mm
Maximum Shrink Fit Outer Diameter30mm
Coil Height42mm
Coil Effective Heating Thickness32mm
Heat Shield Ring
Heating Range3-12mm
Alloy Steel Heating Time6-15s
Stainless Steel Heating Time12-25s
Intelligent Induction SwitchingNo
Coil Positioning Accuracy1mm

Electrical System Parameters

Power TypeSingle-Phase AC
Allowable Voltage Fluctuation RangeAC220V±10%
Insulation ClassClass F
Protection RatingIP54
Grounding RequirementReliable grounding required, grounding resistance ≤1Ω
Overcurrent ProtectionSupported
Overvoltage ProtectionSupported
Overtemperature ProtectionSupported
Short Circuit ProtectionSupported

Cooling System Parameters

Tool Holder Cooling MethodCirculating Water Cooling
Coil Cooling MethodAir Cooling
Cooling Stroke0~300mm
Cooling EfficiencyTool holder cools from 300°C to ambient ≤15s
Air Supply Filtration RequirementThree-Stage Filtration, Water-Free, Dust-Free, Oil-Free

Function Configuration

Core Function 1Scan-to-Identify Heating Parameters
Core Function 2One-Touch Heating
Core Function 3Quick-Change Coil, Intelligent Induction Switching System, Auto Coil Model Recognition
Core Function 4Precise Tool Holder Temperature Control
Core Function 5Capable of Heating Stainless Steel and Alloy Steel Materials
Core Function 6Coil Overtemperature Warning
Core Function 7Tool Holder Overtemperature Automatic Protection
Core Function 8Coil Overtemperature Automatic Protection
Core Function 9Built-in Parameter Library
Core Function 10Supports Multi-Spec Tool Holder Parameter Presets
Core Function 11Supports Auto/Manual Dual Mode Switching
Core Function 12Supports Custom Heating Parameters
Core Function 13Real-Time Heating Process Monitoring
Core Function 14Fault Self-Diagnosis
Core Function 15Real-Time Fault Code Display
Core Function 16Supports Both Shrink Fit and Shrink Removal Modes
Core Function 17Supports Temperature Check for Stainless Steel and Alloy Steel
Core Function 18Circulating water cooling greatly accelerates cooling, reducing time by 75% compared to air cooling

Safety Protection Configuration

Overtemperature ProtectionYes
Overcurrent/Short Circuit ProtectionYes
Leakage ProtectionYes
Air Supply Abnormality ProtectionNo
Coil Abnormality ProtectionYes
Over-Travel ProtectionYes
Emergency Stop ButtonYes
Safety Warning LabelsYes
Insulation ProtectionYes

Human-Machine Interaction System

Display Specification10-inch
Display Resolution1024×600
Operation MethodTouch Screen
Language SupportChinese & English Standard
Parameter SettingsYes
Data DisplayYes
Fault PromptYes
Operation GuideNo

Accessories & Optional Systems

Standard Accessory 1Product Manual, Warranty Card
Standard Accessory 2Shrink Fit Machine Certificate of Conformity
Standard Accessory 3Password Letter
Standard Accessory 4Operation Video QR Code
Standard Accessory 5 - Coolant1L*2
Optional Accessory - Quick-Change CoilK620, K635H, K655, K668
Optional Accessory - Handheld Barcode ScannerQR-LHV01
Optional Accessory - Retaining RingHP-K3, HP-K4, HP-K5, etc.
Optional Accessory - Tool Removal PliersHP-LH7-N
Optional Accessory - Air FilterAF300
Optional Accessory - Heat-Resistant GlovesHP-GT-N
Optional Accessory - Heat Shield RingHG55SR1825
Optional Accessory - Adapter SleeveFull Series Models: SH-BT30/SH-BT40/SH-HSK25, etc.
Optional Accessory - Carbon Deposit Removal PasteQDS-100G
Optional Accessory - Carbon Deposit CleanerHJT-2.9/10
Optional Accessory - Bore Cleaning BrushHP-S3, HP-S4, HP-S5, HP-S6, HP-S8, HP-S10, HP-S12

After-Sales Support Services

Full Machine Warranty Term1 year (non-human-induced damage)
Technical Support7×24 Online Technical Support, Remote Troubleshooting Guidance
On-Site ServiceNationwide on-site installation, debugging & repair service available (except remote areas)
Accessories SupplyLifetime supply of original factory accessories, shipped within 48 hours
Training ServiceFree equipment operation & maintenance training
Software UpgradeLifetime Free Equipment Control System Software Upgrade

Maintenance Requirements

Daily MaintenanceClean Body & Heating Coil After Daily Use, Check Air Supply Lines for Leaks
Weekly MaintenanceClean Air Filter Element Weekly, Check Electrical Connections for Looseness
Monthly MaintenanceCheck Heating Coil Insulation Monthly, Calibrate Temperature Sensor, Lubricate Moving Parts
Quarterly MaintenanceComprehensive Quarterly Check of Electrical, Cooling & Mechanical Transmission System Performance
Annual MaintenanceAnnual Return-to-Factory or On-Site Comprehensive Inspection, Replace Aged Seals, Cables and Other Wear Parts
Storage RequirementsStore in Dry, Ventilated, Corrosive-Gas-Free Environment, Temp -10°C~40°C, RH ≤85%
Transportation RequirementsUse Original Packaging During Transport, Avoid Severe Impact, Inversion, Rain Exposure
Operating Environment RequirementsOperating Temp 5°C~40°C, RH ≤80%, No Dust, No Corrosive Gas, No Strong Electromagnetic Interference

Machine Safety Requirements & Compliance

CE Safety CertificationNo
3C Safety CertificationNo
FCC Safety CertificationNo
EAL Safety CertificationNo
UKCA Safety CertificationNo
PSE Safety CertificationNo
KC Safety CertificationNo
Mechanical StructureMeets
Leveling FeetMeets
Movable GuardNot Applicable
Observation WindowNot Applicable
Emergency Stop ButtonMeets
Control CircuitMeets
Interlock DeviceNot Applicable
Safety Light CurtainNot Applicable
Safety Device LinkageNot Applicable
Two-Hand StartNot Applicable
Lockout/Tagout (LOTO)Not Applicable
Lockout/Tagout (LOTO)Not Applicable
Mechanical StructureMeets
Electrical Control StructureMeets
Circuit BreakerMeets
Power CableMeets
Residual Voltage ProtectionMeets
WiringMeets
Cooling FanMeets
Grounding RequirementMeets
Software LogicMeets
Safety LabelingMeets
Environmental RequirementsMeets
Electrical InspectionMeets
Equipment NameplateMeets
Report Material ProvisionMeets
Automatic Shut-Off ValveNot Applicable
Pipeline ConnectionMeets
Liquid Level SettingNot Met
Installation PositionMeets
Liquid Level Alarm LinkageNot Met
Leak-Proof TrayNot Met
Liquid CollectionNot Applicable
Leak DetectionNot Met
Safety Notice / LabelingMeets
Inspection ReportNot Met
Heating CutoffMeets
Dual Overtemperature Protection ProbesNot Met
Overtemperature Probe Installation PositionMeets
Dual Time ControlNot Met
Circuit LogicNot Met
Overtemperature Protection SettingMeets
Circulating Air HeatingNot Applicable
Environmental RequirementsMeets
Cooling SystemMeets
Cooling System (Standard Reference: GB/T 5959.3)Meets
Occupational HealthMeets
Electrical Control StructureMeets
Safety NoticeMeets
Electrical Control RequirementsMeets
Mechanical StructureMeets
Induction CoilMeets